Image Gallery
-
Learn more
Fixed-Snake – Brain – T2w
MR
FSE T2wResolution: 117um x 120um x 0.3mm
Orientation: Coronal
Slice thickness: 0.3mm / 18 slices
TR: 4000ms / TE: 68ms
FOV: 30×30 / FrxPh: 256×248 / Averages: 4
Acq. time: 8:21Image courtesy of: Dr Radika Michniewicz, Station d'Ecologie Expérimental du CNRS à Moulis & Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Fixed-Lizard – Brain – T2w
MR
FSE T2wResolution: 97um x 100um x 0.5mm
Orientation: Coronal
Slice thickness: 0.5mm / 18 slices
TR: 4000ms / TE: 68ms
FOV: 25×25 / FrxPh: 256×248 / Averages: 4
Acq. time: 8:21Image courtesy of: Dr Radika Michniewicz, Station d'Ecologie Expérimental du CNRS à Moulis & Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Fixed-Fish – Full body – Flash3D
Fish with parasites confirmed by MR.
MR
FLASH 3D 0.5mmOrientation: Coronal
Slice thickness: 20mm
TR: 30ms
FOV: 65×65 / FrxPh: 256×192 / Averages: 1
Acq. time: 6:09Image courtesy of: Dr Radika Michniewicz, Station d'Ecologie Expérimental du CNRS à Moulis & Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Fixed-Fish – Full body – T2w
Fish with parasites confirmed by MR.
MR
FSE T2wOrientation: Coronal
Slice thickness: 1mm / 18 slices
TR: 4000ms / TE: 68ms
FOV: 60×60 / FrxPh: 256×248 / Averages: 4
Acq. time: 8:21Image courtesy of: Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Rat Brain T2W – Axial
MR
FSE T2WResolution: 136um x 141um x 1mm
Orientation: Axial
Slice thickness: 1mm / 28 slices
TR: 4200ms / TE: 68ms
FOV: 35×35 / FrxPh: 256×248 / Averages: 4Image courtesy of: Prof. Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Rat Brain T2w – Coronal
MR
FSE T2wResolution: 156um x 161um x 1mm
Orientation: Coronal
Slice thickness: 1mm / 28 slices
TR: 4200ms / TE: 68ms
FOV: 40×40 / FrxPh: 512×248 / Averages: 4Image courtesy of: Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Rat Brain High Resolution
MR
FSE T2wResolution: 78um x 80um x 750um
Orientation: Sagittal
Slice thickness: 0.75mm / 16 slices
TR: 4800ms / TE: 68ms
FOV: 40×40 / FrxPh: 512×496 / Averages: 16Image courtesy of: Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Mouse Brain Dynamic Contrast Enhanced
IV injection, 0.2ml of Gadolinium at the 3rd minute
MR
FLASH DCEOrientation: Axial
Slice thickness: 1mm / 4 slices / 60 repetitions
TR: 150ms
FOV: 25×25 / FrxPh: 256×160 / Averages: 1
Acq. time: 15 minImage courtesy of: Prof Annemie Van der Linden, Bioimaging Laboratory, University of Antwerp
Learn more
Manage Cookie ConsentWe use cookies to optimize our website and our service.Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.